2202

R/I Transmitter

( Pt100 input )

  • Input for Pt100,Ni100 or Ohm
  • Analog output 0/4..20 mA / 0/2..10 VDC.
  • Individual 0 and 100% adjustment
  • 24VDC Power Supply or Universal Supply 24…230 VAC / 24…250 VDC

 

2914

2-wire room temperature transmitter

  • Measurement range input: 0 to 70 ˚C
  • Supply: 8 to 35 VDC
  • Analogue output: 4 to 20 mA
  • Complete with sensor and transmitter
  • Easy Mounting

 

3101

TC converter

  • High accuracy, better than 1°C or 0.1% of selected range
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppresion
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

 

3102

Pt100 converter

  • High accuracy, better than 0.2°C or 0.1% of selected range
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppresion
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges are selectable via DIP-switches

 

3111

TC Converter - Isolated

  • Excellent accuracy, better than 0.5°C or 0.05% of selected range
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppresion
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges are selectable via DIP-switches

 

3112

Pt100 converter - isolated

  • Excellent accuracy, better than 0.1°C or 0.05% of selected range
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppresion
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

 

3113

HART 7 temperature converter

  • High accuracy, better than 0.05% of span
  • Slimline housing of 6 mm
  • Excellent EMC performance
  • Selectable 60 ms / 60 s response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

 

3331

Temperature converter, loop-powered - isolated

  • Excellent accuracy, better than 0.05% of span
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppression
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

 

3333

Pt100 converter, loop-powered

  • High accuracy, better than 0.1% of span
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppression
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

 
3337
HART 7 temperature converter, loop-powered
  • High accuracy, better than 0.05% of span
  • Slimline housing of 6 mm
  • Excellent EMC performance
  • Selectable 60 ms / 60 s response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

 

5131

2-wire programmable transmitter

  • Input for RTD, TC, mV, linear resistance, mA, and V
  • 3.75 kVAC galvanic isolation
  • 4...20 mA loop output
  • 1- and 2-channel versions
  • ATEX Ex / I.S. version
  • DIN rail mounting
 

5331

2-Wire Programmable Temperature Transmitter

( Pt100 & TC input )

  • RTD, TC, Ohm, or mV input
  • Supply voltage, 8.0...35 VDC
  • Extremely high measurement accuracy
  • For DIN form B sensor head mounting
  • Current 4 to 20 mA output.

 

5334

2-Wire Programmable Temperature Transmitter

( Thermocouple input )

  • TC input
  • High measurement accuracy
  • Galvanic isolation
  • Programmable sensor error value
  • For DIN form B sensor head mounting
  • Current output 4 to 20 mA
  • Supply 7.2 to 35 VDC

 

5337D

2-wire transmitter with HART® protocol

  • RTD, TC, Ohm, and bipolar mV input
  • 2 analogue inputs and 5 device variables with status available
  • HART® protocol revision selectable from HART® 5 or HART® 7
  • Hardware assessed for use in SIL applications
  • Mounting in hazardous gas and dust area

 

5350

Profibus®PA/Foundation Fieldbus Transmitter

  • PROFIBUS ® PA ver. 3.0
  • FOUNDATION Fieldbus ver. ITK 4.6
  • Automatic switch between protocols
  • Linear resistance, postentiometer and bipolar mV measurement.
  • Linearised temperature measurement with RTD or TC sensor.

 

6331

2 - Wire Programmable Transmitter

( Pt100 & TC input high accuracy measurement )

  • RTD, TC, Ohm, or mV input
  • Extremely high measurement accuracy
  • Galvanic isolation
  • Programmable sensor error value
  • 1- or 2- channel version
  • current 4 to 20 mA output.
  • Supply 7.2 to 30 VDC

 

6333

2-Wire Programmable Temperature Transmitter 

(Pt 100 input)

  • RTD ( Pt100, -250 to 850 Deg.C ) or Resistance (  0- 10 Kohm )
  • Current 4-20 mA output.
  • Supply voltage, 8.0...35 VDC
  • DIN Mounting, vertically or horizontally
  • 1 or 2 channel version

 

6334

2-Wire Programmable Temperature Transmitter

( Thermocouple input )

  • TC input
  • Current 4..20 mA Output
  • High measurement accuracy
  • Galvanic isolation
  • Programmable sensor error value
  • 1-or2-channel version
  • Supply 7.2 to 30 VDC

 

6337A

2-wire HART® transmitter

  • 1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals
  • 2 analogue inputs and 5 device variables with status available
  • HART® protocol revision selectable from HART® 5 or HART® 7
  • Hardware assessed for use in SIL applications
  • Mounting on a DIN rail in Safe Area or Zone 2/22