-
Bizsafe 3 logo

Huntsmen (S) Pte Ltd  
Cleanroom M&E Services & Products | Process Instruments

Huntsmen (S) Pte Ltd

 

Ex Barrier

 

5105B

Ex-Isolated Driver

( Transmit signal from safe area to Ex- area )

  • 1- or 2- channel version
  • 3- / 5- port 3.75 kVAC galvanic isolation
  • Driver for Ex area
  • 20 programmable measurement ranges
  • Universal supply by AC or DC

 
5106B
HART® transparent repeater
  • 3- / 5-port 3.75 kVAC galvanic isolation
  • Low response time
  • 2-wire supply > 17 V in Ex / I.S. area
  • 1- or 2-channel version
  • Universal supply by AC or DC
 

5107B

HART® transparent driver

  • 1- or 2-channel version
  • 3- / 5-port 3.75 kVAC galvanic isolation
  • < 1.3 V voltage drop on input
  • 16 V driving voltage on Ex output
  • Universal supply by AC or DC 

 

5202

Pulse Isolator

( Isolation of contact between Ex-area & safe area )

  • 2 channels-2 or 4 outputs
  • Dual output
  • 5-port 3.75 kVAC galvanic isolation
  • Cable error detection
  • Universal AC or DC supply

 

5203B

Ex Solenoid/Alarm Driver

( Audio & Visual alarm application in Ex-area )

  • 1- or 2- channel version
  • Solenoid driver for Ex area
  • 3- / 5- port 3.75 kVAC galvanic isolation
  • Digitally controlled voltage supply for Ex area
  • Universal AC or DC supply

 

5420B

Ex power supply

( 5 ports isolation )

  • 2 channels
  • 5-port 3.75 kVAC galvanic isolation
  • Output voltage > 18 V to Ex area
  • Active current loop detection
  • Universal AC or DC supply

 

7908

System 9000 backplane

  • Provides safe, easy wiring between the backplane and non I.S. automation systems using standard prefabricated I/O cables
  • Direct, Redundant and Duplicate signalling - including HART I/O
  • Robust, compact high-end design solution for 8 system 9000 units
  • Digital Output and LEDs indicate backplane system status

 

7916

System 9000 backplane

  • Provides safe, easy wiring between the backplane and non I.S. automation systems using standard prefabricated I/O cables
  • Direct, Redundant and Duplicate signalling - including HART I/O
  • Robust, compact high-end design solution for 16 system 9000 units
  • Digital Output and LEDs indicate backplane system status

 

7932

System 9000 backplane

  • Provides safe, easy wiring between the backplane and non I.S. automation systems using standard prefabricated I/O cables
  • Direct, Redundant and Duplicate signalling - including HART I/O
  • Robust, compact high-end design solution for 16 system 9000 units
  • Digital Output and LEDs indicate backplane system status

 

9106B

HART® transparent repeater

  • 24 VDC supply via power rail or connectors
  • Active and passive mA input
  • Active or passive output via the same two terminals
  • Splitter function - 1 in and 2 out
  • SIL2/SIL3 Full Assessment and certified acc. to IEC 61508

 

9107B

HART ® Transparent Driver

  • 24 VDC supply via power rail or connectors
  • Fast response time <5 msec
  • High active output load 725 Ohm / 20 mA
  • Output line fault detection via status relay
  • SIL2 certified via Full Assessment according to IEC 61508

 

9113

Temperature/mA Converter

  • Input for RTD, TC and mA
  • Active / passive mA output
  • 1 or 2 channels
  • Can be supplied separately or installed
  • On power rail, PR type 9400
  • SIL 2-certified via Full Assessment

 

9116

Universal Converter

  • Input for RTD, TC, Ohm, potentiometer, mA and V
  • Supply for 2-wire transmitters
  • Active / passive mA output and relay output
  • Can be supplied separately or installed on power rail, PR 9400
  • SIL 2-certified via Full Assessment

 

9202

Pulse Isolator

  • Interface for NAMUR sensors and switches
  • Extended self-diagnostics and detection of cable fault
  • 1 or 2 channels
  • Can be supplied separately or installed on power rail, PR type 9400
  • SIL 2-certified via Full Assessment 

 

9203

IECEx Driver for solenoids, acoustic alarms & LEDs

  • Input for RTD, TC, Ohm, potentiometer, mA and V
  • Supply for 2-wire transmitters
  • Active / passive mA output and relay output
  • Can be supplied separately or installed on power rail, PR 9400
  • SIL 2-certified via Full Assessment